VMware: ALERT: Upgrading ESX 4.0 to 4.0 U1 using Update Manager fails or times out and rebooting the host results in a purple diagnostic screen Symptoms (1016070)

0

When attempting to upgrade ESX 4.0 to ESX 4.0 Update 1, you may experience the following symptoms:

  • Update Manager (VUM) upgrade operation fails or times out at 33%.
  • Upon reboot, the host that was being upgraded displays a purple diagnostic screen with the following error:
    COS Panic: Int3 @ mp_register_ioapic  

Customers using VMware vSphere 4 upgrading to Update 1 with 3rd party management agents running.

To avoid this issue, prior to the update, disable all 3rd party management agents running on the ESX 4.0.0 server before applying the update.

Note: The 3rd party management agents can be enabled after the upgrade is completed.

If you have already updated the ESX host, do not reboot the ESX host. Open a support request with VMware support. For more information, see How to Submit a Support Request.

WARNING: Rebooting the host means the host has to be reinstalled because it is not recoverable after a reboot.

WARNING: If you have virtual machines running on local storage, they may not be retained if you reinstall ESX 4.0 as a result of this issue. Contact VMware Support for assistance in recovering those virtual machines.